Eccentric Isolated Footing Designer — IS 456:2000

Input Data

ParameterValueUnit
Column size — a (along X) × b (along Y) × m
Service axial load Nser (column only; footing weight added internally) kN
Service moments — Mx (about Y-axis) / My (about X-axis) / kN·m
Column position mode —
Physical eccentricity — ex (column C/L offset along X) / ey (along Y) / m
Concrete grade fck MPa
Steel grade fy MPa
Allowable SBC (gross, at foundation level) kN/m²
Auto-suggest B, L, t — fills footing dimensions below (targets 95% SBC) —
Footing plan size — B (along X) × L (along Y) × m
Overall footing thickness t m
Clear cover to bottom bar face (IS 456: min 50 mm for footings on soil) mm
Bottom bar dia — X-dir. ϕx (outer/lower layer) / Y-dir. ϕy (inner layer)
dx = t−cover−ϕx/2  |  dy = t−cover−ϕx−ϕy/2
X: Y: mm
Top bar dia — X-dir. ϕtop,x (outer at top) / Y-dir. ϕtop,y (inner)
dtop,x = t−cover−ϕtop,x/2  |  dtop,y = t−cover−ϕtop,x−ϕtop,y/2
X: Y: mm
Column dowel diameter ϕd mm
⚠ Cover < 50 mm — IS 456 Cl.26.4 recommends min. 50 mm for footings on soil.
⚠ Footing thickness < 250 mm — review shear and punching adequacy.
⚠ dy ≤ 0 — Y-bar inner layer has no effective depth. Increase t or reduce bar sizes / cover.
⚠ Footing smaller than column — B must be > a and L must be > b.
Total ex, ey
—
qmax / qmin (kN/m²)
—
dx / dy / davg (mm)
—

Codal Checks — IS 456:2000

Check Rule / Clause Values & Utilization Status
Fill required inputs (marked *) to begin.

Bottom Steel — X-direction (outer layer, dx)

ParameterValueUnit
Bar diameter ϕx—mm
Effective depth dx—mm
Governing cantilever lx—m
Design moment Mux—kN·m/m
As,x required—mm²/m
Provided spacing—mm c/c
As,x provided—mm²/m

Bottom Steel — Y-direction (inner layer, dy)

ParameterValueUnit
Bar diameter ϕy—mm
Effective depth dy—mm
Governing cantilever ly—m
Design moment Muy—kN·m/m
As,y required—mm²/m
Provided spacing—mm c/c
As,y provided—mm²/m

Top Steel near Column — Hogging (IS 456 strip method)

ParameterValueUnit
Hogging moment — X strip (Mhog,x)—kN·m/m
As,top,x required—mm²/m
Provided spacing — X top (ϕtop,x)—mm c/c
As,top,x provided—mm²/m
Hogging moment — Y strip (Mhog,y)—kN·m/m
As,top,y required—mm²/m
Provided spacing — Y top (ϕtop,y)—mm c/c
As,top,y provided—mm²/m
Min. top steel = 0.12% bD (IS 456 Cl.26.5.2.1) always provided; hogging adds if > min.

Engineering Drawings

Run a calculation to generate drawings.

Bar Bending Schedule (BBS)

Run a calculation to generate BBS.

Design Calculation Summary


Design Assumptions & Method

Disclaimer: This calculator is a design aid based on IS 456:2000. Results must be independently verified by a licensed structural engineer before use in construction. The tool does not account for seismic loads, differential settlement, site-specific conditions, or all detailing requirements. The developer accepts no liability for errors or misuse of results.